- ...][[Category:Macroscale]][[Category:Steel]][[Category:Materials]][[Category:Mechanical Properties]]4 KB (623 words) - 19:21, 14 March 2016
Page text matches
- '''Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility – Part 3: Aero-Acoustic Analyses and Experimental Va ... Hosangadi, A., “Computational Analyses in Support of Sub-Scale Diffuser Testing for the A-3 Facility – Part I: Steady Predictions,” 45th AIAA Joint Pro27 KB (3,996 words) - 19:22, 29 April 2015
- ...VS]] were directed to the correct page. A section for performing [[Instron Testing Machines#Experimental Methods| compression tests]] was then created to brie Here you would describe the methodology for testing the material as well as the Instron machine.37 KB (5,026 words) - 18:30, 21 July 2015
- ... below <ref>[http://www.instron.com/en-us/products/testing-systems Instron Testing Systems], Product descriptions</ref>: ...l''' - Electromechanical testing systems are most commonly used for static testing in a tensile or compression mode within a single frame. Capacities for thes8 KB (1,156 words) - 14:39, 12 February 2015
- ... Nosé-Hoover thermostat was used to regulate the system temperature. The mechanical responses from three different initial configurations were averaged to acco ...al factors on mechanical properties of PE polymer. Results show that many mechanical properties of PE can be simulated by MD in qualitative some times in quanti20 KB (2,429 words) - 18:54, 18 May 2015
- ...emeyer,Y. Hwang,H. Lim,H. El Kadiri, W. Trim "A study on the structure and mechanical behavior of the Terrapene carolina carapace:A pathway to design bio-inspire ...esium using CT Imagery,” Journal for American Society for Nondestructive Testing: Materials Evaluation, Vol. 58, No. 10, p. 1221, 2000.</ref> <br>[[Image:Xr19 KB (2,784 words) - 20:09, 14 March 2016
- ... Nosé-Hoover thermostat was used to regulate the system temperature. The mechanical responses from three different initial configurations were averaged to acco ...nal factors on mechanical properties of PE polymer. Results show that many mechanical properties of PE can be simulated by MD in qualitative some times in quanti11 KB (1,586 words) - 20:26, 23 October 2012
- ...ssue response. The microstructural variations in the tissue were linked to mechanical properties at progressive levels of compression in order to generate struct ===Testing Apparatus===19 KB (2,824 words) - 20:52, 16 June 2011
- ...the inner portion of tendon),among which 3 fascicles were used for tensile testing and 1 was used as a control sample. ...conditioned to a strain of 2%, for 10 cycles at 1 Hz (Yamamoto, 1999). The mechanical data were recorded in engineering stress and engineering strain. Control sa8 KB (1,241 words) - 14:21, 16 April 2015
- microstructure and mechanical property relationships of horn keratin were quantified. These tension and compression, the anisotropy of the material structure and mechanical behavior, the7 KB (1,026 words) - 16:35, 4 February 2011
- ...the inner portion of tendon),among which 3 fascicles were used for tensile testing and 1 was used as a control sample. ...conditioned to a strain of 2%, for 10 cycles at 1 Hz (Yamamoto, 1999). The mechanical data were recorded in engineering stress and engineering strain. Control sa8 KB (1,237 words) - 14:43, 15 April 2015
- ... step was not incorporated into the testing protocol, because the inherent mechanical integrity of the neural tissue was considered to be incapable of maintainin5 KB (816 words) - 22:33, 15 April 2015
- microstructure and mechanical property relationships of horn keratin were quantified. These tension and compression, the anisotropy of the material structure and mechanical behavior, the8 KB (1,141 words) - 18:59, 4 August 2014
- This research effort presents a coupled experimental/modeling study of the mechanical response of porcine brain tissue underwent a non-uniform stress state during testing when glue is used to secure the specimen with the test fixture. This result20 KB (3,098 words) - 20:40, 20 June 2012
- ... University. We would like to extend our thanks to Westmoreland Mechanical Testing and Research Inc., who conducted the static and fatigue experiments for AE49 KB (1,446 words) - 17:12, 5 May 2015
- ...n be assessed and optimized, thereby shortening the costly prototyping and testing cycles. ...nd stress state dependence, as well as failure mechanisms and large-strain mechanical responses. An Internal State Variable Model (ISV)-based model (MSU model)11 KB (1,498 words) - 19:55, 22 August 2012
- ...r, S. H., Bouvard, J.L., Horstemeyer, M.F., “The Anisotropic Compressive Mechanical Properties of the Rabbit Patellar Tendon,” ''Biorheology''. 45, 2008:577- unconfined compression testing, the tendons were thawed and allowed to equilibrate for 30 min in 0.9%10 KB (1,510 words) - 16:13, 30 July 2014
- ...ature male white New Zealand rabbits and were mounted on a custom-designed testing device, quickly followed by application of predetermined sim-ple shear stra ...oughout the specimen preparation and assembly process leading up to actual testing were kept wet with PBS to prevent loss of tissue fluid. The tendon was kept11 KB (1,718 words) - 14:26, 16 April 2015
- ...tress states, which had previously only been shown in tension. Interrupted mechanical tests revealed differences in the morphological microstructure evolution th === Mechanical Testing ===14 KB (2,058 words) - 22:14, 4 June 2012
- This paper presents a coupled experimental/modeling study of the mechanical response of porcine brain tissue underwent a non-uniform stress state during testing when glue is used to secure the specimen with the test fixture. This result5 KB (748 words) - 03:12, 4 May 2015
- ...</ref> as quasi-static preconditioning has no meaning for high strain rate testing as conducted in this study. ...le1.bmp|thumb|center|550px|Table 1. Details of samples, animal numbers and testing conditions are each strain rate.]]3 KB (393 words) - 14:28, 16 April 2015