# # Info file : MDRcopy/armcoiron/info.dat # Data file : MDRcopy/armcoiron/n1r2n3.a1 # Comment : TRUE STRESS V. TRUE STRAIN; MAX DIA=0.6; UNNOTCHED; DIAMETRICAL DISPLACEMENT WAS USED # Source : HONEYWELL; G.R. JOHNSON AND T.J. HOLMQUIST; TEST DATA AND COMPUTATIONAL STRENGTH AND FRACTURE MODEL CONSTANTS FOR 23 MATERIALS SUBJECTED TO LARGE STRAINS, HIGH STRAIN RATES, AND HIGH TEMPERATURES; SEPTEMBER 1988 # Test type : NOTCHED TENSILE TEST # 0 4 293.000 0.200000E-02 0.00000 0.00000 -0.0012469 0.52287 -0.0017864 28.172 -0.0027912 62.082 -0.002264 82.426 0.006385 101.19 0.02288 131.94 0.038688 160.42 0.060174 189.94 0.086037 218.76 0.11952 250.86 0.15604 278.78 0.20136 307.55 0.2428 331.64 0.29932 356.05 0.36841 380.95 0.45895 409.98 0.54758 437.8 0.63236 462.32 0.7165 486.85 0.81073 512.75 0.91573 542.1 1.0036 566.79 1.0884 590.79 1.1662 613.07 1.2377 632.57 1.3262 655.87 1.4476 687.97 1.5695 717.32 1.6669 742.15 1.7838 770.76 1.8766 791.99